APPLICATION
Solar Model 9355-1 Pulse Generator is designed to provide impulse excitation by means of an injection probe placed around interconnecting cables or power wires. The unit uses
a charged transmission line (50 ohms) to generate a pulse with less than 2 nanoseconds rise and fall time, and duration of approximately 30 nS, calibrated in a 50 ohm fixture to deliver up to 5 amperes at a rate of 30 p.p.s. for one minute as required by
MIL-STD-461D/E, test method
CS115.
DESCRIPTION
The charged line potential of the Model 9355-1 is adjustable from less than 2 volts to greater than 2000 volts. The repetition rate is variable from less than 0.6 p.p.s. to greater than 150 p.p.s., or single pulses manually triggered by a panel mounted push button. Digital displays monitor the charging voltage and pulse repetition rate. This unit can also be used as an impulse calibrator to provide an adjustable spectral output up to 150 dB µV/MHz over the frequency range of 1 KHz to 10 MHz constant within
±1 dB.
|
|
SPECIFICATIONS
OUTPUT PULSE:
Charging Voltage: Adj. from 0 to 2000 volts
Rise/Fall Time: <2 nanoseconds
Duration Time: 35 nanoseconds
Pulse Repetition Rate: 0.6 p.p.s. to
150 p.p.s.
Polarity: ±selectable
Output Load: 50 ± j 0 ohms
SPECTRAL OUTPUT:
Frequency Range: 1 KHz to 10 MHz
Output Level into 50Ω: Up to 150 dB µV/MHz
Output Flatness: ±1 dB
FEATURES
- Panel-mounted digital meters monitor
the adjustable charged line voltage
and pulse repetition rate.
- Adjustable pulse rate from 0.6 p.p.s. to 150 p.p.s., and manual triggering via
front panel push button.
- Charged line output voltage adjustable from 1.0 V to >2000 V.
- Pulse generator with spectral output calibrated in terms of dB V/MHz into
a 50 ohm load.
|
|
ACCESSORIES RECOMMENDED FOR CS115 TESTING
Type 9233-50-TS-50-N Line Impedance Stabilization Network.
Type 9125-1 Calibration Fixture used to calibrate probes with a window size from 1.25" to 1.50" and a frequency range of 20 Hz to 500 MHz.
Type 9142-1N Current Injection Probe with a frequency range of 2 MHz to 450 MHz, 200 W.
Type 9123-1 Current Monitor Probe with a frequency range of 10 KHz to 500 MHz, 1.25" window.
Type 9410-1 High Voltage 40 dB Attenuator, dc to 1 GHz, 40 dB insertion loss, ±2 dB. Can also be used as a high voltage, 50 ohm coaxial load.
Type 9841-1 1000 Volt Termination, 50 ohm coaxial 1 W average power. Typical input VSWR in a 50 ohm system under 1.5 from DC to 1 GHz. |