Model 8850-2 High Power Sweep Generator

for Conducted Audio Frequency Susceptibility Testing

SPECIFICATIONS

Frequency Range: 30 Hz to 150 kHz in four
bands
Frequency Stability : <2250 ppm/C
Output Power: 200 watts into 2.0 Ω non-inductive
Output Impedance: 2.0 Ω
Output Voltage: ≥20 volts r.m.s. into 2.0 Ω non-inductive
Output Current: 15 amperes maximum at 1 kHz.
Output Level: Manually controlled by panel
knob. Continuously displayed on digital
panel meter.
Sweep Duration: 0.0333 x frequency of oscillation per sec.
Remote Sense: Automatically maintains output voltage at the level set by the operator, up to 7.5 volts r.m.s., as frequency is scanned to 50 kHz.
Output Level Drift: Less than 0.5%.
Overload Protection: Automatic shut down for excess temperature, over-voltage, or over-current conditions in output circuit.

Power Requirements
Power Source: 115/230 V 60/50 Hz
Power Line Fuses 115 V: 12 amperes (2)
Power Line Fuses 230 V: 5 amperes (2)

Physical Dimensions
Net Weight: 39 Lbs (17.7. Kg)
Shipping Weight: 45 Lbs (20.4. Kg)
Height: 9.12 Inches (22.2 cm)
Width: 17.12 Inches (43.5 cm)
Depth: 13.50 Inches (34.3 cm)

 

 

 

Click on chart for larger image.

 