APPLICATION
The Model 8850-2 200-watt High Power Sweep Generator was specifically designed for use with the Solar Audio Isolation Transformers in making audio frequency susceptibility tests as required by MIL-STD-461E/F CS101. This high power unit is especially suited for rapidly making
tests in the shielded room.
When used with the Type 6220-1A or 6220-2 Audio Isolation Transformer, the combination enables the injection of sinewave audio voltages into active power lines supplying power to Equipment Under Test (EUT).
DESCRIPTION
The Model 8850-2 Power Sweep Generator provides audio power in a manually tuned or sweeping mode for four frequency bands covering 30 Hz to 150 KHz. The sweep rate is compliant with the requirements of Mil-Std-461F for an analog scan, approximately 0.0333 x frequency of oscillation per second.
|
The frequency in kHz and output level in volts r.m.s. are continuously displayed on two digital front panel meters.
When used in conjunction with the Type 7021-1 Phase Shift Network and the Type 6220-1A Audio Isolation Transformer, provision is made for sensing the audio voltage being injected into the EUT and displaying it on the digital panel meter. In this arrangement, the unit maintains a constant injection level (up to a maximum of 7.5 volts r.m.s.) as the frequency is scanned to 50 kHz.
FEATURES
- Manual or automatic frequency sweep from 30 Hz to 150 KHz.
- Digital display of frequency and output
voltage level or injected voltage level.
- Remote sensing of voltage being
injected into the Equipment Under Test.
- Automatic leveling of output voltage as
frequency is scanned or swept to 50 kHz.
- Low output impedance for greater transfer of audio power.
- Protective circuits prevent damage
to output stage caused by power frequency feedback in typical a.c.
test setups.
- Up to 200 watts output into 2.0 ohm resistive load.
|
AVAILABLE ACCESSORIES
Type 6220-1A Audio Isolation Transformer. Use for injecting output of 8850-2 in series with power line to test sample as required by test method CS101.
Type 7021-1 Phase Shift Network.Use for removing the power frequency from the voltmeter in CS101 tests.
Type 7032-1 Isolation Transformer.Use for removing power ground from the case of scope or voltmeter.
Type 8810-1 Impedance Matching Transformer. Plugs into output terminals to step up the output to 50 ohms impedance. Use when a 50
ohm signal source is needed.
Type 8811-1 Wide Range Transformer. Plugs into output terminals to provide up to 115 volts
r.m.s. at 200 watts. Use as a power source for frequencies from 30 Hz to 2 KHz.
Type 9138-1 Step-up Transformer.Plugs into output terminals to provide up to 2 KV into 20,000 ohm load, 3 kHz to 30 kHz.
|