Model 8282-1 Transient Pulse Generator

for Conducted Transient Susceptibility Testing, 0.15 µS - 5.0 µS - 10.0 µS up to 600 volts (peak)

  • Adjustable pulse position on a.c. power lines relates the transient susceptibility to the real time aspects of digital circuitry served
    by a.c. power.
  • Transients can be injected in synchronism with repetitive
    circuit functions as required by
    Method CS06
    of MIL-STD-462.
  • Remote triggering of single or repetitive pulses in terms of particular system characteristics.
  • The upper terminals of the PARALLEL pair and the SERIES pair provide a positive-going spike on the 5 µS and the 10 µS modes. These terminals deliver a negative-going spike in the 0.15 µS mode. When the test plan requires both
    a positive and a negative spike,
    it is necessary to reverse the connections to the output terminals of the Model 8282-1 Spike Generator.

SPECIFICATIONS

Spike Durations: Pushbutton selectable durations of 0.15 µS, 5.0 µS and 10.0 µS (±20%) to zero crossover, into 5.0 ohm resistive load.

Adjustable Peak Amplitude: Up to 600 volts for 0.15 µS, 5.0 µS and 10.0 µS durations into five ohm non-inductive load.

Internal Impedance: Less than 5.0 ohms for 0.15 µS, less than 2.0 ohms for 5.0 µS, less than 1.0 ohm for 10.0 µS.

Pulse Repetition Rate: Manually adjustable up to 50 p.p.s. for all pulse durations.

Pulse Shape: Ringing characteristic similar to Figure 19 in MIL-STD-462 when connected to non-inductive load.

 

 


Click on charts for larger image

Pulse Position: Adjustable from 0° to 360° on 50 Hz, 60 Hz or 400 Hz power lines.

External Sync Operation: Remotely triggerable up to 50 p.p.s. for 0.15 µS, up to 1000 p.p.s. for 5.0 and 10.0 µS.

Amplitude Display: Panel meter is analog LED display of peak amplitude as it would be into a five ohm resistive load.

Power Current in Series Injection Mode: Handles up to 50 amperes of current at power frequencies.

Power Requirements: 115 volts 60 Hz, 3.0 amperes. (230 volts 50 Hz, 1.5 ampere available.)

Size: 12.25" wide , 8.7" high 13" deep. (311 mm x 211 mm x 330 mm.)

Weight: 30 pounds.

USEFUL ACCESSORIES

Type 7115-2 High Voltage Pulse Transformer. Plugs into SERIES output terminals to provide transient levels up to 15 KV, peak, into Type 7510-1 Spark Gap assembly for static discharge tests.

Type 7512-1 Spike Injection Probe*

Type 7519-1 Pulse Shaping Network*

Type 7541-1 Spike Receptor Probe*

 

 

Type 8282-150 Transient Pulse Transformer. Plugs into SERIES output terminals. Handles up to 150 amperes through the secondary for high current test samples.

Type 8525-1 Non-Inductive Five
Ohm Load

Type 8527-2 Transient Pulse Transformer. Plugs into SERIES output terminals to provide spike levels up to 2 KV, peak, into 50 ohms when using the ten microsecond function.

Type 8908-1 Transient Pulse Transformer. Plugs into series output to provide up to 600 V spike into 50 ohms when using 5 µS or 10 µS function.

Type 9007-1 Transient Pulse Transformer. Plugs into SERIES output terminals to provide spike levels up to 1200 V into 50 ohms when using the 0.15 microsecond function.

* See Application Note on Cable Induced Transients

Back to Category Index Page | Refer to Page 20 of the Catalog « Previous Page