Model 7054-1 Spike Generator 600 volts

for Conducted Transient Susceptibility Testing Up to 600 volts peak

SPECIFICATIONS

Spike Amplitude: Continuously adjustable from less than 10 volts to more than 250 volts peak.

Repetition Rate: Continuously adjustable from 0.8 to 10 p.p.s.

Rise Time:Less than 1.0 microsecond, into 5 ohm resistive load.

Spike Duration:Output falls to zero in approximately 10 microseconds.

Spike Shape:See curve. Similar to Figure 19 of MIL-STD-462.

 

 

 

 

Phase Adjustment: Spike position adjustable from 0° to 360° periodically on 50, 60 or 400 Hz sine wave.

Internal Impedance: Less than 0.5 ohm.

Output Power:More than 300 kw peak into 0.5 ohm load.

Power Current in Series Injection Mode: Handles up to 25 amperes of current at power frequencies.

Power Requirements:115 volts 60 Hz, 1.6 amperes. (230 volts 50 Hz, 0.8 ampere available. )

Size:Standard rack panel:7" high, 19" wide, 12.75" deep.(17.78 cm x 48.26 cm x 32.38 cm.)

 

 

AVAILABLE ACCESSORIES

Type 7332-1 Transient Pulse Transformer. Plugs into SERIES output terminals of 7054-1A to provide spike levels up to 600 volts, peak, into 6 ohm load.

Type 7406-1 Transient Pulse Transformer. Plugs into SERIES output terminals of 7054-1 to provide spike levels up to 1200 volts, peak, into 50 ohm load.

Type 8525-1 Noninductive Five Ohm Load.

Type 8527-1 Transient Pulse Transformer. Plugs into SERIES output terminals of 7054-1 to provide spike levels up to 2 KV, peak, into 50 ohm load.


Click on charts for larger image.

Back to Category Index Page | Refer to Page 24 in the Catalog « Previous Page