SPECIFICATIONS
Spike Amplitude: Continuously adjustable from less than 10 volts to more than 250 volts peak.
Repetition Rate: Continuously adjustable from 0.8 to 10 p.p.s.
Rise Time:Less than 1.0 microsecond, into 5 ohm resistive load.
Spike Duration:Output falls to zero in approximately 10 microseconds.
Spike Shape:See curve. Similar to Figure 19 of MIL-STD-462.
|
|
Phase Adjustment: Spike position adjustable from 0° to 360° periodically on 50, 60 or 400 Hz sine wave.
Internal Impedance: Less than 0.5 ohm.
Output Power:More than 300 kw peak into 0.5 ohm load.
Power Current in Series Injection Mode: Handles up to 25 amperes of current at power frequencies.
Power Requirements:115 volts 60 Hz, 1.6 amperes. (230 volts 50 Hz, 0.8 ampere available. )
Size:Standard rack panel:7" high, 19" wide, 12.75" deep.(17.78 cm x 48.26 cm x 32.38 cm.)
|
|
AVAILABLE ACCESSORIES
Type 7332-1 Transient Pulse Transformer. Plugs into SERIES output terminals of 7054-1A to provide spike levels up to 600 volts, peak, into 6 ohm load.
Type 7406-1 Transient Pulse Transformer. Plugs into SERIES output terminals of 7054-1 to provide spike levels up to 1200 volts, peak, into 50 ohm load.
Type 8525-1 Noninductive Five Ohm Load.
Type 8527-1 Transient Pulse Transformer. Plugs into SERIES output terminals of 7054-1 to provide spike levels up to 2 KV, peak, into 50 ohm load.
|