Model 6254-5S RFI Transient Generator

for Conducted Transient Susceptibility Testing Up to 250 volts, peak

SPECIFICATIONS

Spike Amplitude: Continuously adjustable from less than 10 volts to more than 250 volts peak.

Repetition Rate: Continuously adjustable from 0.5 to 500 p.p.s.

Rise Time: Less than 1.0 microsecond.

Spike Duration: Output falls to zero in
approximately 8 to 14 microseconds.

Spike Shape: Ringing characteristic as shown in Figure 19 of MIL-STD-462.

Phase Adjustment: Spike position adjustable from 0° to 360° on 50, 60
or 400 Hz lines.

 

Sync Operation: Triggers at any rate
from once every ten seconds to over
800 transients per second.

Internal Impedance: 0.5 ohm.

Output Power: More than 35 kw peak into 0.5 ohm load.

Power Current in Series Injection Mode: Handles up to 50 amperes at power frequencies.

Power Requirements: 115 volts 60 Hz, 1.8 amperes. (230 volts 50 Hz, 0.9 ampere available.)

Size: 8.125" wide, 9" high, 14.625" deep. (20.64 cm x 22.86 cm x 37.15 cm.)

 

 

AVAILABLE ACCESSORIES

Type 6254-150 Transient Pulse Transformer. Plugs into SERIES output terminals. Handles up to 150 amperes through the secondary for high current test samples.

Type 7115-1 High Voltage Transient Transformer. Plugs into SERIES output terminals to provide transient levels up to 15 KV peak, into spark gap for static discharge tests.

Type 7802-1 Transient Pulse Transformer. Plugs into SERIES output terminals to provide up to
450 volts peak, into 12 ohms.

 


Click on charts for larger image.

Back to Category Index Page | Refer to Page 26 in the Catalog « Previous Page